EEG and Motion Signals Pilot Dataset
Generated from data/catalog/registry.yaml@2026-09-17. Values marked TODO(confirm) await the author's catalog.
Description
TODO(confirm) — the author’s catalog does not hold this dataset (§10.1 rule 3); this page carries only the §10.2 facts until a registry stub is added (§10.11 item 8).
Curriculum role: one CSV, ~67 s, 10.1 MB
Citation
- Paper DOI: TODO(confirm)
- Dataset DOI: 10.5281/zenodo.22093536
- Reference: Iwendi, C., NWibo, E., & Uwah, S. E. (2026). EEG and Motion Signals Pilot Dataset. Zenodo. doi:10.5281/zenodo.22093536
Download and access
| Field | Value |
|---|---|
| Official source | https://zenodo.org/records/22093536 |
| Access class | open |
| Size | 10.1 MB, one file |
| Format | csv |
| BIDS | false |
| Mirrors | none recorded |
License
- Name: CC-BY-4.0
- Note (verbatim from the directory): cc-by-4.0 in the record metadata and on the landing page (legalcode link), read 2026-09-21; a single CSV, so no LICENSE file to disagree — site/notes/data-p5-licences.md §5
- Snippets on this site: allowed — the site may ship short derived snippets and precomputed products from this dataset, labelled as derivatives (re-referenced, filtered, cropped) with citation, license and DOI.
Acquisition
| Field | Value |
|---|---|
| Device | 4-channel wireless dry-electrode headband (Muse S), as the record states; exported by the Mind Monitor app |
| Device class | consumer |
| Channels | 4 (TP9, AF7, AF8, TP10 as RAW_* columns beside the app’s per-band columns (Delta … Gamma per channel), AUX, accelerometer and gyroscope, HSI_* contact indicators, HeadBandOn, Battery and an Elements marker column — 40 columns read from the file’s first 64 kB on 2026-09-21; the RAW_* values sit near 800 on the app’s own scale, not in microvolts (TODO(confirm) the conversion)) |
| Sampling rate (Hz) | 256 (≈256 Hz effective per the record’s description (17,155 rows over ~67 s); rows are stamped to the millisecond and the band columns repeat between raw samples, so the rate is counted, not read) |
| Online filters | TODO(confirm): the app’s export; whether its notch was on is not stated |
| Reference | TODO(confirm) |
| Mains frequency (Hz) | 50 |
| Paradigms | rest-pilot |
| Participants | 1 |
| Population | one pilot recording, one person; demographics undocumented |
| Clinical groups | none |
| Sessions | 1 |
| Durations | one CSV, ~67 s, 10.1 MB |
Used on this site
Directory only — no lesson, widget, notebook or capstone uses this dataset.
Loader
Fetches only the stated subset. Recorded loader: pandas.read_csv; RAW_TP9, RAW_AF7, RAW_AF8, RAW_TP10 are the raw columns.
TODO(confirm) — the catalog records no loader for this dataset.
Caveats worth knowing
- A single 67-s pilot recording of one person: an example of an export’s shape (raw beside vendor band features and contact indicators on the frontotemporal-4 geometry), not a dataset to draw a conclusion from.
- The RAW_* columns are on the app’s own scale, not microvolts; the conversion is TODO(confirm).
- Directory-only: no registry entry until the author adds one (§10.1 rule 3); nothing on the site derives from it.
Related datasets
Citation
Iwendi, C., NWibo, E., & Uwah, S. E. (2026). EEG and Motion Signals Pilot Dataset. Zenodo. doi:10.5281/zenodo.22093536
- Paper DOI
- TODO(confirm)
- Dataset DOI
- 10.5281/zenodo.22093536
A BibTeX button appears only when every BibTeX field is available in the catalog (§10.8); none is available yet.
Download
- Official source
- https://zenodo.org/records/22093536
- Access class
- open
- Size
- 10.1 MB, one file
- Format
- csv
- BIDS
- no
License
- Name
- CC-BY-4.0
- Note
- cc-by-4.0 in the record metadata and on the landing page (legalcode link), read 2026-09-21; a single CSV, so no LICENSE file to disagree — site/notes/data-p5-licences.md §5
- On this site
- Short derived snippets and precomputed products (cropped, re-referenced, filtered) may appear in labs and figures, labelled as derivatives with this license and DOI. Notebooks download only the subset they need from the official source.
Acquisition
| Device | 4-channel wireless dry-electrode headband (Muse S), as the record states; exported by the Mind Monitor app |
|---|---|
| Device class | consumer |
| Channels | 4 — TP9, AF7, AF8, TP10 as RAW_* columns beside the app's per-band columns (Delta … Gamma per channel), AUX, accelerometer and gyroscope, HSI_* contact indicators, HeadBandOn, Battery and an Elements marker column — 40 columns read from the file's first 64 kB on 2026-09-21; the RAW_* values sit near 800 on the app's own scale, not in microvolts (TODO(confirm) the conversion) |
| Sampling rate | 256 Hz — ≈256 Hz effective per the record's description (17,155 rows over ~67 s); rows are stamped to the millisecond and the band columns repeat between raw samples, so the rate is counted, not read |
| Online filters | TODO(confirm): the app's export; whether its notch was on is not stated |
| Reference | TODO(confirm) |
| Mains frequency | 50 Hz |
| Paradigms | rest-pilot |
| Subjects | 1 |
| Sessions | 1 |
| Durations | one CSV, ~67 s, 10.1 MB |
| Population | one pilot recording, one person; demographics undocumented |
| Clinical groups | none (healthy only) |
Used on this site
Directory only — no lesson, widget, notebook or capstone uses this dataset.
Loader
# Loader recorded in the catalog: pandas.read_csv; RAW_TP9, RAW_AF7, RAW_AF8, RAW_TP10 are the raw columns
# TODO(confirm) the exact call and the subset to fetch. Official source: https://zenodo.org/records/22093536
Caveats worth knowing
- A single 67-s pilot recording of one person: an example of an export's shape (raw beside vendor band features and contact indicators on the frontotemporal-4 geometry), not a dataset to draw a conclusion from.
- The RAW_* columns are on the app's own scale, not microvolts; the conversion is TODO(confirm).
- Directory-only: no registry entry until the author adds one (§10.1 rule 3); nothing on the site derives from it.
Related datasets
- Muse EEG Subconscious Decisions Dataset (directory, scalp)
- PhySF, Physiological Sense of Flow (directory, scalp)
- UNIVERSE: UNobtrusIVE measuRement of mental workload and stress in uncontrolled environments (directory, scalp)
- ArEEG_Words (elective, scalp)
- EEG Dataset for Nonlinear Dynamics-Based Characterization of Cognitive States in Engineering Students (elective, scalp)